Enclosure (1) to COMDTINST 6260.21B
Percent Volatiles By Volume: 100.0
Viscosity:
pH:
Form (Radioactive Matl):
Magnetism (Milligauss):
Corrosion Rate (IPY):
Autoignition Temperature: 928F
=================================================================
Fire and Explosion Hazard Data
=================================================================
Flash Point: 12F/-11C
Flash Point Method: C.C
Lower Explosive Limit: 1.3
Upper Explosive Limit: 7.9
Extinguishing Media: DRY CHEMICAL, CO2, HALON, FOAM.
Special Fire Fighting Proc: USE NIOSH/MSHA APPROVED SCBA IN AN ENCLOSED AREA
WITH FULL PROTECTION.
Unusual Fire and Expl. Hazrd.s: AVOID TOXIC VAPORS (SUSPECTED HUMAN
CARCINOGEN)
=================================================================
=================================================================
Stability: YES
Conditions To Avoid (Stability): HEAT, SPARKS AND OPEN FLAMES.
Materials To Avoid: OXIDIZERS, ACIDS, PEROXIDES, CHLORINE, OTHER HALOGENS,
METALS.
Hazardous Decomp Products: TOXIC OXIDES OF CARBONS.
Hazardous Poly Occur:
Conditions To Avoid (Poly):
=================================================================
Health Hazard Data
=================================================================
LD50-LC50 Mixture: ORAL RAT: 4700MG/KG
Route Of Entry - Inhalation: YES
Route Of Entry - Skin: YES
Route Of Entry - Ingestion: YES
Health Hazards Acute And Chronic: ACUTE: IRRITATION OF EYES, SKIN AND
RESPIRATORY TRACT, BURNING SENSATION OF EYES, PULMONARY
EDEMA, CNS EFFECTS, HEADACHE, NAUSEA, VOMITING, DROWSINESS,
WEAKNESS, BLURRED VISION. CHRONIC: DERMATITIS, DRYING OF
SKIN, CNS EFFECTS, HEMATOPOIETIC AND IMMUNE SYSTEMS, ANEMIA
WHICH MAY BE HOMOCHROMIC.
Carcinogenity - NTP: YES
Carcinogenity - IARC: YES
Carcinogenity - OSHA: YES
3