FIRE EXTINGUISHERS
APPLIES TO:
ALL COMMERCIAL FISHING VESSELS EXCEPT SOME OUTBOARD
BOATS OF OPEN CONSTRUCTION LESS THAN 26 FEET IN LENGTH.
________________________________________________________________________
REQUIREMENTS:
-Less than 26 feet:
Requires one B-I
-26 ft & over but less than 40 feet:
Requires two B-I
-40 ft & over but less than 65 feet:
Requires three B-I
-VSLS 65 feet or more:
See the table on the following page.
________________________________________________________________________
STANDARD:
_________________________________________________________________________
INSTRUCTORS NOTES:
-Fire extinguishers must be readily available.
-Coast Guard Approved extinguishers are identified by the following
marking on the label such as:
Marine Type USCG Approved, Size..., Type..., 162.028
-Excess extinguishers do not have to be Coast Guard approved, but
must be listed and labeled by a nationally recognized laboratory.
-One B-II replaces Two B-I Fire Extinguishers
-A Coast Guard Approved Installed System for the engine room replaces
one B-I Fire Extinguisher.
-Outboard boats less than 26 feet are not required to carry fire